This helps with the interpretation of log messages, for the MBB.

Message Component Interpretation
Riding MBB This is a data logging record, taken every 1 minute by default.
Charging MBB This is a charging logging record, taken every 10 minutes by default.
"Stats Read Failed, Resetting All Stats to Defaults"
ABS SILA reporting an error
BMS 1 Internal Disable Received BMS
BMS Reset Unknown BMS The BMS Reset Procedure was performed.
BT RX buffer reset
Bad read pointer 0xFFFFFFFF is outside log bounds
Battery module contactor closed
Bike Shut Off After Idle For 3600 seconds.
CHECK SUCCESSFUL
CPU Soft
Calex 1200W Charger 1 Connected Onboard Charger SDS Platform only, but occurs on all Gen2 models.
Calex 1200W Charger 1 Disconnected Onboard Charger SDS Platform only, but occurs on all Gen2 models.
Calex 720W Charger 0 Connected Onboard Charger XMX Platform only, but occurs on all Gen2 models.
Calex 720W Charger 0 Disconnected Onboard Charger XMX Platform only, but occurs on all Gen2 models.
Disabling Calex 1200W Charger 1 Onboard Charger SDS Platform only, but occurs on all Gen2 models.
Disabling Calex 720W Charger 0 Onboard Charger XMX Platform only, but occurs on all Gen2 models.
Disabling External Chg 0 Charger 2
Disabling External Chg 1 Charger 3
Disarmed
Enabling Calex 1200W Charger 1 Onboard Charger SDS Platform only, but occurs on all Gen2 models.
Enabling Calex 720W Charger 0 Onboard Charger XMX Platform only, but occurs on all Gen2 models.
Enabling External Chg 0 Charger 2
Enabling External Chg 1 Charger 3
Entering Bootloader by request
Entering Charge Standby Mode
Entering Critical Error Shutdown
Event Log detected a bad
Event Log reformatted due to bad read pointer.
Event Log reformatted due to bad write pointer.
Event Log signature restored
Entered Test Mode
Exited Test Mode
Entering Hibernate
Exiting Hibernate
External Chg 0 Charger 2 Connected
External Chg 0 Charger 2 Disconnected
External Chg 1 Charger 3 Connected
External Chg 1 Charger 3 Disconnected
Key Off Ignition The bike was keyed off (intentionally or via electrical fault).
Key On Ignition The bike was keyed on (intentionally or via electrical fault).
Leaving Charge Standby Mode
Log data at offset 0x0:
Max allowed voltage difference is 500mV
Model year set to 2019 via CAN
Module CAN Link Down BMS
Module CAN Link Up BMS
Module Closing Contactor BMS
Module Contactor is now Closed BMS
Module Contactor is now Open BMS
Module Opening Contactor BMS
Module Registered BMS
Module State Change Requires Disconnect BMS
Module mode Change Does Not Require Disconnect BMS
Module not connected BMS
Module scheme changed from ??? mode to ??? mode BMS
Modes
  • None
  • Charging
  • Running
  • Stopped
New Rev ?? is replacing Rev ?? MBB Firmware update
Power Off Key Switch Ignition The bike was keyed off (intentionally or via electrical fault).
Power Off Onboard Charger Onboard Charger The bike was turned off by the onboard charger being unplugged or disengaged.
Power On Key Switch Ignition The bike was keyed on (intentionally or via electrical fault).
Power On Onboard Charger Onboard Charger The bike was turned on by the onboard charger being plugged in.
Powertank voltage too high and monolith ineligible for connection. Setting powertank as ineligible for connecton. Power Tank
Precharge Decay Too Steep. Restarting Sevcon. Sevcon motor controller
RN42 configuration complete
SEVCON CAN EMCY Frame Error Motor Controller
Set Model to DS via CAN
Set VIN to 538S????????????? via CAN
Sevcon CAN Link Up Motor Controller
Sevcon Contactor Drive OFF Motor Controller
Sevcon Contactor Drive ON. Motor Controller
Sevcon Entered Preop Mode Motor Controller
Sevcon Turned Off Motor Controller
Sevcon Turned On Motor Controller